Search...

INOF5 Fat Analyzer

INOF406
INOF406

INOF5 Fat Analyzer

INOF5 Fat Analyzer is based on the Soxhlet extraction principle and integrates such functions as soaking, extraction, leaching, heating, condensation and solvent recovery. It features sealed metal bath heating with automatic temperature control, ensuring uniform heating and safe operation; six samples can be tested at the same time, and optimal temperature can be selected according to the difference between reagent boiling point and ambient temperature so as to achieve quick analysis; reagents can also be recycled to reduce test cost; and soaking, extraction and solvent recovery can be done in one step. Therefore, this device is characterized by reasonable design, stable performance, good reproducibility, high accuracy, easy operation, saving time and effort, and so on.

Renseignez-vous maintenant

CARACTÉRISTIQUES

Scope of application:
INOF5 Fat Analyzer can quickly separate one substance from solid or semi-solid mixtures, can determine the soluble organic compounds contained in foods, feeds, medicines, soil, sludge, polymers, fiber products, petrochemical products, detergents, rubber, plastics and other materials.


Feature:

· Integral metal heating, while scope and high precision of temperature control
· Electric circuit is isolated from the extraction space, ensuring devices security
· Over-temperature alarming and timer reminding functions are available
· Timer circuit is isolated from the extraction space, ensuring device security
· Triple alarms i.e. sound, light, LCD screen word prompts are available
· Abundant interface contents give simultaneous display of given temperature, actual    temperature, given time and heating   time
· The lifting connection of linear bearing conduction technique gives smooth and comfortable   lifting operation
· Intelligent man-machine dialogue control system
· Exclusive air insulation technique leaves the case in room temperature, has thermal insulation    and temperature   maintenance two functions
· 4.3" LCD screen and microcomputer control system are adopted


SPECIFICATIONS

Technical parameter
Temperature rangeRoom temperature +5℃~280℃
Measuring range0.1~100%
Temperature accuracy±1℃
Sample weight0.5~15g(generally 2~5g,depending on sample)
Capacity per batch6pcs/batch
Solvent cup volume80mL
Solvent recovery≥80%
Shortened extraction time20~80%
Power supply220VAC±10%, 50Hz
Power1KW
Dimensions650mm×320mm×715mm
Net Weight35Kg


ACCESSOIRES

Aluminum heating cup for storage and heating of solvents.


Filter paper frame, used to hold samples and filter paper.